Gas Analyzer

Flue Gas Analyzer System (ZSU)
Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc
Japanese type approval

Flue Gas Analyzer System (ZSJ)
Simultaneous and continuous measurement of up to 5 components
Single beam, sample switching system Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Sample switching system ensures zero-point stability
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc
Japanese type approval

Flue Gas Analyzer System (ZSU-7)
Continuous monitoring of 7 components:- NOx, SO2, CO, CO2, O2, HCl, and dust
Ideal for environmental monitoring
Space-saving design
All the necessary equipment are housed in a cabinet of 1215 (W) x 700 (D) x 1780 (H) mm size
Less electrical work: signal and power terminals are in one place
Maintenance-free HCl measurement
Japanese type approval (NOx, SO2, CO, O2)
Saves power by 40% compared to conventional models

CO & O2 Analyzer System (ZSQ)
Continuous monitoring of CO and O2 in flue gas
Temperature recording
CO concentration recording
CO peak count alarm
Japanese type approval certified

Cross Stack Laser Gas Analyzer (ZSS)
Continuous monitoring of HCl, NH3, CO, CO2, CH4, and O2
Fast response ≤ 5 seconds (≤ 2 seconds version available)—suited for use in a control system
Dual-beam version available for CO + CO2 or CO + O2 simultaneous measurement
O2 analyzer with the instrument air purge system available
Low maintenance and long-term superior stability
Suited for measurement under high temperature and dusty environment
Optical path length (stack diameter) 0.5–10 m
Hardly affected by interference from other gases

Zirconia Oxygen Analyzer
Gas sampling device is unnecessary : For quick response, insert the detector directly into the flue Gas sampling functions such as a gas aspirator and a dehumidifi er are not required
Easy maintenance : The sensor equipped with the detector, has unit construction, it is easy to replace. By separating the detector and the flow guide tube, filter replacement is easy
More reliable than sensor diagnosis, sensor recoverable function : Depending on the concentration of the measurement gas, the power of the sensor might deteriorate. The equipment includes sensor recovery function electronically, checking the deterioration status of the sensor depletion.Therefore, it has high reliability and long-lasting stability
Safe and secure : System detects thermocouple break for heater control on the sensor side. Safety functions of isolating power supply to the detector or isolating power via external contact input are also
Easy operation : The operation and setting for the converter can be performed interactivelly, and available as English, Japanese or Chinese for language display